{"id":22401,"date":"2026-07-10T13:39:40","date_gmt":"2026-07-10T10:39:40","guid":{"rendered":"https:\/\/labostera.lt\/?post_type=product&#038;p=22401"},"modified":"2026-07-10T13:56:28","modified_gmt":"2026-07-10T10:56:28","slug":"farmacines-stabilumo-tyrimu-kameros-pharmaceutical-stability-test-chamber-ptc-series","status":"publish","type":"product","link":"https:\/\/labostera.lt\/lv\/priemones-ir-iranga\/laboratorine-iranga\/medziagotyra\/stabilumo-ir-parametru-palaikymo-kameros\/farmacines-stabilumo-tyrimu-kameros-pharmaceutical-stability-test-chamber-ptc-series\/","title":{"rendered":"Farmaceitisk\u0101s stabilit\u0101tes testa kamera (PTC s\u0113rija)"},"content":{"rendered":"<p data-path-to-node=\"15\">Farm\u0101cijas nozar\u0113 farmaceitisko l\u012bdzek\u013cu kvalit\u0101tes kontrole un stabilit\u0101tes test\u0113\u0161ana ir absol\u016bti kritiski posmi, bez kuriem nav iesp\u0113jams nevienam jaunam medikamentam vai medic\u012bnas produktam non\u0101kt tirg\u016b. Saska\u0146\u0101 ar glob\u0101laj\u0101m ICH (Starptautisk\u0101 padome cilv\u0113kiem paredz\u0113to z\u0101\u013cu re\u0123istr\u0101cijas pras\u012bbu saska\u0146o\u0161anai) vadl\u012bnij\u0101m katrs izveidotais prepar\u0101ts ir r\u016bp\u012bgi j\u0101p\u0101rbauda da\u017e\u0101dos, prec\u012bzi noteiktos temperat\u016bras un mitruma apst\u0101k\u013cos. \u0160ie testi \u013cauj noteikt produkta der\u012bguma termi\u0146u, identific\u0113t no\u0101rd\u012b\u0161an\u0101s produktus un nov\u0113rt\u0113t iepakojuma integrit\u0101ti da\u017e\u0101d\u0101s klimatiskaj\u0101s zon\u0101s. Tie\u0161i lai izpild\u012btu \u0161\u012bs \u0101rk\u0101rt\u012bgi stingr\u0101s pras\u012bbas, tika izveidota Jiupo PTC s\u0113rijas farmaceitisk\u0101s stabilit\u0101tes test\u0113\u0161anas kameru l\u012bnija. \u0160\u012bs ier\u012bces rada un uztur bezkompromisa mikroklimata stabilit\u0101ti, \u013caujot laboratorij\u0101m p\u0101rliecino\u0161i veikt ilgtermi\u0146a testus vai pa\u0101trin\u0101tas noveco\u0161anas testus, piln\u012bb\u0101 nov\u0113r\u0161ot \u0101r\u0113j\u0101s vides ietekmi uz rezult\u0101tiem.<\/p>\n<p data-path-to-node=\"16\">Lai nodro\u0161in\u0101tu absol\u016btu temperat\u016bras un mitruma vienm\u0113r\u012bgumu vis\u0101 kameras tilpum\u0101, \u0161aj\u0101s sist\u0113m\u0101s tiek izmantota inovat\u012bva perfor\u0113tas aizmugur\u0113j\u0101s sienas gaisa sadales tehnolo\u0123ija. At\u0161\u0137ir\u012bb\u0101 no standarta laboratorijas ledusskapjiem, kur gaiss tiek p\u016bsts no viena konkr\u0113ta punkta un neizb\u0113gami rada temperat\u016bras at\u0161\u0137ir\u012bbas starp plauktiem da\u017e\u0101dos augstumos, PTC s\u0113rij\u0101 gaisa pl\u016bsma p\u0101rvietojas horizont\u0101li pa visu plauktu laukumu. Tas noz\u012bm\u0113, ka testa paraugi, kas atrodas pa\u0161\u0101 aug\u0161pus\u0113, izj\u016bt tie\u0161i t\u0101dus pa\u0161us klimatiskos apst\u0101k\u013cus k\u0101 paraugi pa\u0161\u0101 apak\u0161\u0101. Kamer\u0101 uzst\u0101d\u012btie augst\u0101k\u0101s precizit\u0101tes elektroniskie mitruma un temperat\u016bras sensori nep\u0101rtraukti v\u0101c datus un nos\u016bta tos PID mikrodatoram, kas ar mikroimpulsiem acumirkl\u012b piel\u0101go sild\u012b\u0161anas, dzes\u0113\u0161anas un tvaika \u0123ener\u0113\u0161anas modu\u013cus, saglab\u0101jot parametru sv\u0101rst\u012bbas maz\u0101kas par pusgr\u0101du.<\/p>\n<p data-path-to-node=\"17\">Atz\u012bstot, ka kvalit\u0101tes kontroles laboratoriju darba slodze ir \u013coti at\u0161\u0137ir\u012bga, \u0161\u012b konsolid\u0113t\u0101 iek\u0101rtu l\u012bnija pied\u0101v\u0101 visaptvero\u0161u un \u013coti elast\u012bgu izm\u0113ru diapazonu. Maz\u0101m testa grup\u0101m vai pilotpartiju test\u0113\u0161anai ide\u0101li piem\u0113rots ir kompaktais PTC100 modelis ar 105 litru ietilp\u012bbu. Vid\u0113ja lieluma laboratorij\u0101m, kas katru dienu apstr\u0101d\u0101 standarta paraugu apjomus, ir paredz\u0113ti PTC300 (330 litri) un PTC500 (484 litri) mode\u013ci. Lai atvieglotu piek\u013cuvi pla\u0161i izvietotiem z\u0101\u013cu iepakojumiem, ra\u017eot\u0101js pied\u0101v\u0101 divdurvju PTC500D modeli (489 litri). Palielinoties test\u0113\u0161anas pl\u016bsm\u0101m, ir iesp\u0113jams uzlabot ier\u012bces uz PTC600 (621 litrs) un PTC800 (773 litri). Tikm\u0113r liel\u0101m farmaceitiskaj\u0101m r\u016bpn\u012bc\u0101m, kur\u0101m j\u0101uzglab\u0101 t\u016bksto\u0161iem paraugu, ir pieejami mode\u013ci ar milz\u012bgu ietilp\u012bbu: PTC1000 ar 1227 litru ietilp\u012bbu, PTC1600 ar 1743 litru ietilp\u012bbu un s\u0113rijas liel\u0101kais flagmanis \u2013 PTC2000, kas nodro\u0161ina iespaid\u012bgus 2244 litrus. Ir svar\u012bgi atz\u012bm\u0113t, ka visiem \u0161iem mode\u013ciem ir vien\u0101da vad\u012bbas lo\u0123ika un tehnolo\u0123isk\u0101 uzticam\u012bba.<\/p>\n<p data-path-to-node=\"18\">Kameru meh\u0101niskais dizains ir izstr\u0101d\u0101ts, \u0146emot v\u0113r\u0101 tikai iztur\u012bbu un atbilst\u012bbu GLP un GMP prakses standartiem. Kameras iek\u0161\u0113j\u0101s sienas un plaukti ir izgatavoti no spogu\u013capdares ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda, kas nov\u0113r\u0161 bakt\u0113riju uzkr\u0101\u0161anos un \u013cauj \u0101tri dezinfic\u0113t. Durvis ir apr\u012bkotas ar r\u016bpnieciskiem, daudzpak\u0101pju bl\u012bv\u0113jumiem, kas piln\u012bb\u0101 nov\u0113r\u0161 telpas gaisa iek\u013c\u016b\u0161anu, un sp\u0113c\u012bgi blo\u0137\u0113\u0161anas meh\u0101nismi aizsarg\u0101 v\u0113rt\u012bgus p\u0113tniec\u012bbas paraugus no nesankcion\u0113tas piek\u013cuves. Lai garant\u0113tu nep\u0101rtrauktu darb\u012bbu, augst\u0101kas klases iek\u0101rt\u0101s tiek izmantoti divi, p\u0101rmai\u0146us darbojo\u0161ies kompresori. \u0160\u012b tehnolo\u0123isk\u0101 redundances sist\u0113ma noz\u012bm\u0113, ka, vienam kompresoram darbojoties, otrs netiek akt\u012bvi izmantots, un pirm\u0101 kompresora negaid\u012btas atteices gad\u012bjum\u0101 otrais autom\u0101tiski p\u0101r\u0146em visu sist\u0113mas slodzi, t\u0101d\u0113j\u0101di pasarg\u0101jot vair\u0101kus m\u0113ne\u0161us ilgu p\u0113t\u012bjumu no sabrukuma.<\/p>\n<p data-path-to-node=\"19\">M\u016bsdienu farm\u0101cijas nozar\u0113 datu dro\u0161\u012bba un izsekojam\u012bba tiek v\u0113rt\u0113ta tikpat stingri k\u0101 pa\u0161i klimata parametri. T\u0101p\u0113c PTC s\u0113rijas kameras ir apr\u012bkotas ar modern\u0101m digit\u0101laj\u0101m datu ierakst\u012b\u0161anas sist\u0113m\u0101m. Visas mikroklimata izmai\u0146as tiek past\u0101v\u012bgi arhiv\u0113tas sist\u0113mas iek\u0161\u0113j\u0101 atmi\u0146\u0101, t\u0101s var lejupiel\u0101d\u0113t jebkur\u0101 laik\u0101, izmantojot USB savienojumu, vai ar\u012b tie\u0161i un nep\u0101rtraukti p\u0101rs\u016bt\u012bt uz centr\u0101l\u0101s laboratorijas LIMS sist\u0113mu, izmantojot standarta RS485 komunik\u0101cijas saskarni. Jebkuras \u0101rk\u0101rtas situ\u0101cijas gad\u012bjum\u0101, piem\u0113ram, \u016bdens padeves p\u0101rtraukuma ap\u016bde\u0146o\u0161anas sist\u0113m\u0101, ier\u012bce nekav\u0113joties aktiviz\u0113 ska\u0146as sign\u0101lus un aizsarg\u0101 paraugus. Izv\u0113loties \u0161o apr\u012bkojumu, uz\u0146\u0113mumi ieg\u016bst jaud\u012bgu instrumentu, kas \u013cauj tiem p\u0101rliecino\u0161i pieg\u0101d\u0101t augst\u0101k\u0101s kvalit\u0101tes farmaceitiskos produktus pasaules tirg\u016b, piln\u012bb\u0101 iev\u0113rojot starptautisk\u0101s audita pras\u012bbas.<\/p>\n<table data-path-to-node=\"20\">\n<thead>\n<tr>\n<td><strong>Galven\u0101s specifik\u0101cijas<\/strong><\/td>\n<td><strong>Tehniskie parametri<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"20,1,0,0\"><b data-path-to-node=\"20,1,0,0\" data-index-in-node=\"0\">Temperat\u016bras diapazons<\/b><\/span><\/td>\n<td><span data-path-to-node=\"20,1,1,0\">0 ~ 70 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"20,2,0,0\"><b data-path-to-node=\"20,2,0,0\" data-index-in-node=\"0\">Mitruma diapazons<\/b><\/span><\/td>\n<td><span data-path-to-node=\"20,2,1,0\">10 ~ 95 % relat\u012bvais mitrums<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"20,3,0,0\"><b data-path-to-node=\"20,3,0,0\" data-index-in-node=\"0\">Temperat\u016bras sv\u0101rst\u012bbas<\/b><\/span><\/td>\n<td><span data-path-to-node=\"20,3,1,0\">\u2264 0,5\u00a0\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"20,4,0,0\"><b data-path-to-node=\"20,4,0,0\" data-index-in-node=\"0\">Mitruma sv\u0101rst\u012bbas<\/b><\/span><\/td>\n<td><span data-path-to-node=\"20,4,1,0\">\u2264 3 % relat\u012bvais mitrums<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"20,5,0,0\"><b data-path-to-node=\"20,5,0,0\" data-index-in-node=\"0\">Gaisa sadales sist\u0113ma<\/b><\/span><\/td>\n<td><span data-path-to-node=\"20,5,1,0\">Horizont\u0101la pl\u016bsmas perfor\u0113ta siena<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"20,6,0,0\"><b data-path-to-node=\"20,6,0,0\" data-index-in-node=\"0\">Pieejamie mode\u013ci un apjomi<\/b><\/span><\/td>\n<td>\n<p data-path-to-node=\"20,6,1,0\">PTC100 (105 l), PTC300 (330 l), PTC500 (484 l), PTC500D (489 l)<\/p>\n<p>&nbsp;<\/p>\n<p data-path-to-node=\"20,6,1,2\">PTC600 (621L), PTC800 (773L), PTC1000 (1227L)<\/p>\n<p>&nbsp;<\/p>\n<p data-path-to-node=\"20,6,1,4\">PTC1600 (1743L), PTC2000 (2244L)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"20,7,0,0\"><b data-path-to-node=\"20,7,0,0\" data-index-in-node=\"0\">Atbilst\u012bba vadl\u012bnij\u0101m<\/b><\/span><\/td>\n<td><span data-path-to-node=\"20,7,1,0\">ICH Q1A, GLP, GMP standarti<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>\u201eJiupo PTC s\u0113rijas farmaceitisk\u0101s stabilit\u0101tes kameras ir b\u016btiskas kvalit\u0101tes kontroles iek\u0101rtas, kas izstr\u0101d\u0101tas, lai atbilstu augst\u0101kajiem standartiem medic\u012bnas, biotehnolo\u0123ijas un farm\u0101cijas nozar\u0113s. Pamatojoties uz starptautiskaj\u0101m ICH vadl\u012bnij\u0101m, \u0161\u012bs kameras ir ide\u0101li piem\u0113rotas farmaceitisko l\u012bdzek\u013cu der\u012bguma termi\u0146a noteik\u0161anai, pa\u0101trin\u0101tas noveco\u0161an\u0101s testiem un ilgtermi\u0146a stabilit\u0101tes testiem da\u017e\u0101d\u0101s klimata zon\u0101s. Apvienot\u0101 s\u0113rija pied\u0101v\u0101 \u0101rk\u0101rt\u012bgi pla\u0161u iesp\u0113ju kl\u0101stu, s\u0101kot no kompakta 105 litru s\u0101kuma l\u012bme\u0146a mode\u013ca l\u012bdz mas\u012bvai 2244 litru sist\u0113mai liela apjoma ra\u017eo\u0161anas r\u016bpn\u012bc\u0101m. Iek\u0101rt\u0101m ir nevainojama siltumizol\u0101cija, vieda horizont\u0101la gaisa sadales sist\u0113ma un dubl\u0113jo\u0161i kompresori, kas garant\u0113 absol\u016btu temperat\u016bras un mitruma parametru vienm\u0113r\u012bgumu katru dienu, pat nep\u0101rtrauktas test\u0113\u0161anas laik\u0101 vair\u0101kus gadus.<\/p>","protected":false},"featured_media":22404,"template":"","meta":[],"product_brand":[1115],"product_cat":[1114],"product_tag":[],"class_list":["post-22401","product","type-product","status-publish","has-post-thumbnail","product_brand-jiupo","product_cat-stabilumo-ir-parametru-palaikymo-kameros","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/product\/22401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/media\/22404"}],"wp:attachment":[{"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/media?parent=22401"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/product_brand?post=22401"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/product_cat?post=22401"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/labostera.lt\/lv\/wp-json\/wp\/v2\/product_tag?post=22401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}